TDK-Micronas HVC 5x
Jump to navigation
Jump to search
The TDK-Micronas HVC 5x are Arm Cortex-M3 CPU based microcontroller for motor-controll applications.
Flash Banks
HVC 5481G, HVC 5422D
| Flash bank | Base address | J-Link support | Flasher support | Loader | |
|---|---|---|---|---|---|
| Name | Bank size | ||||
| Program flash | 0x00200000 | Default | 64 KB | ||
| NVR flash | 0x00290000 | Default | 1 KB | ||
| EEPROM | 0x002A0000 | Default | 2 KB | ||
HVC 5223C, HVC 5222C, HVC 5221D, HVC 5221D
| Flash bank | Base address | J-Link support | Flasher support | Loader | |
|---|---|---|---|---|---|
| Name | Bank size | ||||
| Program flash | 0x00200000 | Default | 32 KB | ||
| NVR flash | 0x00290000 | Default | 256 KB | ||
| EEPROM | 0x002A0000 | Default | 512 KB | ||
HVC 5220D, 5222D
| Flash bank | Base address | J-Link support | Flasher support | Loader | |
|---|---|---|---|---|---|
| Name | Bank size | ||||
| Program flash | 0x00200000 | Default | 32 KB | ||
| NVR flash | 0x00290000 | Default | 1 KB | ||
| EEPROM | 0x002A0000 | Default | 2 KB | ||
Watchdog Handling
- The device has a watchdog WWDG(Window Watchdog).
- If the watchdog is enabled, it is turned off during flash programming and turned back on afterwards.
Device Specific Handling
Reset
- The device uses normal Cortex-M reset, no special handling necessary, like described here.
Security
- The device has a readout protection located at 0x00200020, which has to be 0xFFFFFFFF in order to be disabled.