Revision as of 11:31, 17 July 2025 by Nino (talk | contribs) (Created page with "This page contains the mechanical and electrical specifications of the SEGGER '''J-Trace PRO RISC-V V3'''. <br> For information on the general specifications as well as an overview of supported software features refer to J-Trace PRO Cortex. == Specifications == {| class="seggertable" |- ! Specification !! Value |- !colspan="2"| General |- | Supported OS || Microsoft Windows (x86/x64), Linux (x86/x64/Arm), macOS...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

This page contains the mechanical and electrical specifications of the SEGGER J-Trace PRO RISC-V V3.
For information on the general specifications as well as an overview of supported software features refer to J-Trace PRO Cortex.

Specifications

Specification Value
General
Supported OS Microsoft Windows (x86/x64), Linux (x86/x64/Arm), macOS (x86/Apple M1)
Electromagnetic compatibility (EMC) EN 55022, EN 55024
Operating temperature +5°C ... +60°C
Storage temperature -20°C ... +65 °C
Relative humidity (non-condensing) Max. 90% rH
Mechanical
Size (without cables) 123mm x 68mm x 30mm
Weight (without cables) 120g
Available interfaces
Ethernet interface Gigabit
USB interface USB 3.0, SuperSpeed
Target interface JTAG/SWD 20-pin (14-pin adapter available)
JTAG/SWD + Trace 19-pin
JTAG/SWD Interface, electrical
Power supply USB-powered (max. 400mA)
Target interface voltage (VIF) 1.2V ... 5V
LOW level input voltage (VIL) VIL <= 40% of VIF
HIGH level input voltage (VIH) VIH >= 60% of VIF
Reset Type Open drain. Can be pulled low or tristated.
JTAG/SWD Interface, Timing
Data input rise time (Trdi) Trdi <= 20ns
Data input fall time (Tfdi) Tfdi <= 20ns
Data output rise time (Trdo) Trdo <= 10ns
Data output fall time (Tfdo) Tfdo <= 10ns
Clock rise time (Trc) Trc <= 10ns
Clock fall time (Tfc) Tfc <= 10ns
Trace interface, electrical
Power supply USB-powered (max. 400mA)
Target interface voltage (VIF) 1.2V ... 5V
LOW level input voltage (VIL) VIL <= 40% of VIF
HIGH level input voltage (VIH) VIH >= 60% of VIF
Capacitive load 3 pF J-Trace + 8 pF cable (typical)
Trace interface
Max. trace clock frequency 150 MHz